WHAT ARE YOU LOOKING FOR?
Products
  • Balcony System
    Upgrade your balcony into a clean energy source with our ​high-efficiency Solar Balcony Mounting Brackets. Designed for urban apartments, homes, and commercial spaces, these ​lightweight yet durable​ brackets provide a ​quick, no-drill installation​ solution for solar panels on railings, walls, or flat surfaces. Adantages: Space-Saving Design   Quick Installation   ​Engineered for Safety   Optimized […]
  • Test Report – 1#Beam + 80H

      Tags :

    In order to make our client to believe us, we conducted tests on our products.   Pull test   The test result have shown that the maximum force have reached 24.23kN, and the displacement at maximum force have reached 20.63mm. And this is the force-displacement curve  
  • Test Report – 1#Beam +120H

      Tags :

    In order to make our client to believe us, we conducted tests on our products.   Pull test   The test result have shown that the maximum force have reached 34.07kN, and the displacement at maximum force have reached 32.11mm. And this is the force-displacement curve  
  • Test Report – Middle Clamp

      Tags :

    In order to make our client to believe us, we conducted tests on our products.   Pull test   The test result have shown that the maximum force have reached 17.29kN, and the displacement at maximum force have reached 5.17mm. And this is the force-displacement curve  
  • Test Report – 2#Beam+120H

      Tags :

    In order to make our client to believe us, we conducted tests on our products.   Pull test   The test result have shown that the maximum force have reached 42.61kN, and the displacement at maximum force have reached 24.61mm. And this is the force-displacement curve  
  • Test Report – End Clamp

      Tags :

    In order to make our client to believe us, we conducted tests on our products.   Pull test   The test result have shown that the maximum force have reached 8.49kN, and the displacement at maximum force have reached 6.21mm. And this is the force-displacement curve  
  • Test Report – Rail Clamp

      Tags :

    In order to make our client to believe us, we conducted tests on our products.   Pull test   The test result have shown that the maximum force have reached 10.06kN, and the displacement at maximum force have reached 10.12mm. And this is the force-displacement curve  
  • Test Report – 2#Beam + 80H

      Tags :

    In order to make our client to believe us, we conducted tests on our products.   Pull test   The test result have shown that the maximum force have reached 25.50kN, and the displacement at maximum force have reached 22.54mm. And this is the force-displacement curve  